RSSI OSP Counter |
(Trunking Wide, RSSI Thresholds) |
![]()
Selects the number of ASTRO 25 OSPs RSSI Outbound Signaling Packets (OSP) for which the radio must remain inactive on the Control Channel before a set of RSSI samples is taken. This value should be set with the assumption of single Trunking Signaling Block (TSBK) channel format (1 OSP = 37.5 msec). If the channel is actually double or triple TSBK format, the codeplug value will be scaled so that the time interval the radio uses to remain inactive is equal to: RSSI OSP Counter * 37.5 msec. This selection can apply for all Trunking Systems and therefore to all Trunking Personalities.
![]()
|
Do not attempt to modify this RSSI setting unless you are very knowledgeable in the workings of this feature. Incorrect settings may cause your radio to be incapable of communications with the FNE (Fixed Network Equipment). |
![]()
When the radio is model / option capable.
![]()
Minimum |
Maximum |
40 |
255 |